- Arthur Marsh (arthur@gateway.dircsa.org.au) wrote:
- : G. Dragon (Vadim@infsviaz.msk.su) wrote:
- [edited]
- : : I had the same problem connecting Motorolas 326x V.34 and ZyXels V.32bis.
- : : I believe that's because both V.34 and V.32bis protocols have adaptive
- : : features (i.e. before establishing connection they try to evaluate the
- : : line quality and choose proper transmission parameters).
- : : As a result, while Motorola ("V.34 Auto" Mode) was trying to quess the
- : : required protocol, ZyXel made attempts to optimize its parameters and
- : : that "duel of intellects" lasted till timeout. When I put Motorola
- : : into "V.32bis Auto" mode, all became ok.
-
- : I had problems calling from my Motorola Codex 3265 Fast V.34 modem to
- : the Motorola ISG bbs, even though both modems were the 3265 with revision
- : 7.1 firmware.
-
- : The solution was for Telstra to fix their echo cancellers, both by a
- : firmware upgrade of the Coherent echo cancellers and tweaking the
- : Alcatel S12 built-in echo cancellers so that PLAIN 2100 Hz tones
- : *reliably* activate the echo canceller, even on noisy lines, and that
- : 2100 Hz tones WITH PHASE REVERSALS did not activate the echo cancellers,
- : even on noisy lines, and that the echo canceller only cut out when there
- : was a loss of energy in *both* directions (V.34 always has energy in at
- : least one direction).
-
- : By reliably, I also meant that the once the echo canceller cut in, it
- : stayed active until the G.165 loss of energy in both directions timeout.
-
- : I can now connect to the Motorola ISG bbs at 26400/24000 bps from Australia.
-
- Connections to the Zyxel USA support bbs have improved from 14400 bps /V.34 to
- 16800 bps /V.34 since Telstra fixed their echo cancellers also.
-
- --
- Arthur Marsh, telephone +61-8-370-2365, fax +61-8-223-5082
- arthur@dircsa.org.au