  9. References: <4f9f9c$civ@gateway.dircsa.org.au>
  10. NNTP-Posting-Host: gateway.dircsa.org.au
  11. X-Newsreader: TIN [version 1.1 PL8]
  12.  
  13. Arthur Marsh (arthur@gateway.dircsa.org.au) wrote:
  14. : G. Dragon (Vadim@infsviaz.msk.su) wrote:
  15. [edited]
  16. : : I had the same problem connecting Motorolas 326x V.34 and ZyXels V.32bis.
  17. : : I believe that's because both V.34 and V.32bis protocols have adaptive
  18. : : features (i.e. before establishing connection they try to evaluate the
  19. : : line quality and choose proper transmission parameters).
  20. : : As a result, while Motorola ("V.34 Auto" Mode) was trying to quess the
  21. : : required protocol, ZyXel made attempts to optimize its parameters and
  22. : : that "duel of intellects" lasted till timeout. When I put Motorola
  23. : : into "V.32bis Auto" mode, all became ok.
  24.  
  25. : I had problems calling from my Motorola Codex 3265 Fast V.34 modem to
  26. : the Motorola ISG bbs, even though both modems were the 3265 with revision
  27. : 7.1 firmware.
  28.  
  29. : The solution was for Telstra to fix their echo cancellers, both by a
  30. : firmware upgrade of the Coherent echo cancellers and tweaking the 
  31. : Alcatel S12 built-in echo cancellers so that PLAIN 2100 Hz tones 
  32. : *reliably* activate the echo canceller, even on noisy lines, and that
  33. : 2100 Hz tones WITH PHASE REVERSALS did not activate the echo cancellers,
  34. : even on noisy lines, and that the echo canceller only cut out when there
  35. : was a loss of energy in *both* directions (V.34 always has energy in at
  36. : least one direction).
  37.  
  38. : By reliably, I also meant that the once the echo canceller cut in, it 
  39. : stayed active until the G.165 loss of energy in both directions timeout.
  40.  
  41. : I can now connect to the Motorola ISG bbs at 26400/24000 bps from Australia.
  42.  
  43. Connections to the Zyxel USA support bbs have improved from 14400 bps /V.34 to
  44. 16800 bps /V.34 since Telstra fixed their echo cancellers also.
  45.  